RAP Research on Artificial Persons Lab
Field setup manual · 22 September 2026

BIOPAC Research Ring Setup Guide

A practical, image-led workflow for charging, fitting, pairing, recording, syncing, and troubleshooting the research ring used in RAP Lab.

iOS
Senstream is iPhone/iPad only.There is no Android version. Use an iPhone or iPad for ring setup, firmware updates, and Senstream recording. Firmware updates require iOS/iPadOS 16.6 or later.
00 / START

Preflight checklist

Before starting a participant session, make sure the hardware, fit, app, and storage state are ready.

Bring
  • BIOPAC Research Ring
  • Magnetic USB-A charging cable
  • USB power adapter — not included with the ring
  • Correct clear sizing shim
  • iPhone or iPad with Senstream installed
Confirm
  • Ring has been charged
  • Sensor block touches palm-side skin
  • Ring appears inside Senstream — not iOS Bluetooth Settings
  • Required recording configuration is selected
  • Ring is off the charger before recording
Fast workflow: charge → fit shim → wear snugly → add ring in Senstream → choose configuration → remove from charger → record → confirm cloud checkmark or local-file location.
01 / SYSTEM

Know the ring

The May 2026 BIOPAC product sheet identifies the device as AT01. The exact model printed on this lab package has not yet been verified.

Measured signals

EDA, PPG, brief ECG, temperature, and accelerometry.

Derived outputs

Heart rate (HR) and heart-rate variability (HRV).

Wireless link

Bluetooth Low Energy.

Battery

Runtime may exceed 8 hours, depending on enabled channels and sampling.

Cloud

charts.senstream.com is listed as the cloud portal. Portal access has not yet been verified in this setup.

Multi-ring option

Optional ACK100W-RNG AcqKnowledge Ring Software supports up to 9 rings per computer.

Continuous ECG needs additional hardware

Use the RESRING-ECG-ADAPT together with the RESRING-LEAD. The ring itself is listed for brief ECG.

02 / SETUP

Complete setup, in order

Follow these steps from power to pairing. Fit is not cosmetic: stable sensor-to-skin contact is essential for uninterrupted data.

Charge the ring

Seat the ring on the magnetic charger. An internal glow is visible while it charges. A full charge from empty takes about 2 hours.

The cable ends in USB-A; a power adapter is not included.

BIOPAC Research Ring seated on its magnetic USB-A charging cable.
FIG. 01Seat the ring fully on the magnetic charger; the setup showed an internal charging glow.

Select the sizing shim

Choose the clear sizing insert that removes slack and keeps the finger pressed against the sensor block. The shim used in this setup is marked size 9.

Fit targetSnug and stable, without the sensor block lifting away from the skin.
Clear size 9 sizing shim held beside the BIOPAC Research Ring.
FIG. 02Clear size 9 insert used to remove slack and maintain sensor contact.

Insert the shim

Slide the shim into the ring band. Seat the shim’s curved channel inside the band and make sure its clips engage the band.

The clear shim sliding into the inside of the ring band.
FIG. 03Insert orientation: curved channel seated inside the band, clips engaging the band.

Position the sensor block

The sensor block contains the gold EDA electrodes and the PPG optical window — the dark square with the red optical element visible in the close-up.

Place this complete sensor area against the palm-side skin of the finger, with firm, continuous contact.

Close-up of the gold EDA electrodes and the dark PPG optical window.
FIG. 04The gold EDA electrodes and dark PPG optical window must touch palm-side skin.

Wear the ring at the finger base

Push the ring down toward the base of the finger. It should hold securely against the skin and resist sliding during recording.

If another finger gives a more stable fit, use it. The middle finger produced a snugger fit during troubleshooting.

The ring worn snugly at the base of the finger.
FIG. 05Wear the ring snugly at the base of the finger to reduce slipping and dropouts.

Install Senstream

Install Senstream on an iPhone or iPad. Senstream is available only on iOS/iPadOS; there is no Android version.

Firmware requirementRing firmware updates require Senstream on iOS/iPadOS 16.6 or later.

Add the ring inside Senstream

Do not pair the ring from iOS Settings → Bluetooth.

The ring does not appear there. Open Senstream and add the ring from inside the app. In this setup, the app displayed ring ID 20540 and “1 Ring Connected.”

03 / RECORD

Start and monitor a session

Use the recording dialog to name the session, select the signal configuration, and begin acquisition.

Start sequence

  1. Tap Record New Session.
  2. Open the Record Session dialog.
  3. Choose New Recording Session.
  4. Select a recording configuration.
  5. Take the ring off its charger when prompted: “Remove Ring from Charger.”
  6. Start the recording.
Senstream Record Session dialog showing ring connection and recording configurations.
FIG. 06Record Session dialog showing the connected ring and configurations A and B.

Available configurations seen in this setup

ConfigurationChannels and ratesNote
APPG 200 Hz · EDA 5 Hz · Temperature 5 HzSelected in this setup
BECG 200 Hz · PPG 25 Hz · EDA 5 HzShown in the app

During recording

The session screen shows live traces for PPG, EDA, temperature, and acceleration, a pulsing PPG trace, and a session timer.

A Mark Event button is visible. Its behavior was not verified during this setup, so this guide does not assign it a function.

Keep the signal stable

Keep the hand still, avoid rotating the ring, and watch for a continued live trace rather than a “No Finger” state.

04 / DATA

Cloud sync and app settings

The setup account is signed into Senstream Cloud. Confirm storage and synchronization before ending the workflow.

Cloud state observed

Senstream Cloud was signed in as Chinonso Anyaehie (infosysscholar@gmail.com).

Recorded sessions display green cloud checkmarks when synced. Storage can be changed with Switch to Local Files Browser.

After every sessionConfirm the expected session appears and, for cloud storage, that its green cloud checkmark is visible.
Senstream Settings screen with storage, help, and about options.
FIG. 07Settings provides storage, cloud-account, help, and about controls.
Session storage

Switch to Local Files Browser
Senstream Cloud account
Delete Account
Sign Out

Help

User Guide
Contact Support

About

Visit Senstream.com
What’s New

05 / FIX

Troubleshooting “No Finger”

During this setup, “No Finger” dropouts were linked to intermittent skin contact.

Symptom
Live acquisition drops to “No Finger” or the session stops updating.
Cause observed
The sensor block is losing firm, continuous contact with the finger.

1 · Re-seat

Push the ring toward the base of the finger.

2 · Reduce slack

Add the correct sizing shim and ensure it is clipped into the band.

3 · Minimize motion

Keep the hand still during recording.

4 · Try another finger

The middle finger gave a snugger fit during this session.

5 · Warm cold hands

The room was 20.2°C; cold hands may have contributed to contact or signal instability.

6 · Restart cleanly

After correcting the fit, end the frozen session and start a new one.

Do not guess from light colorsThis guide does not assign meanings to LED colors or patterns because those meanings were not verified in the setup session.
06 / STATUS

What is verified — and what is not

This boundary keeps the guide honest and tells the next operator exactly where testing should continue.

Verified working

  • Charging with visible internal glow
  • Size 9 shim fit and insertion
  • Base-of-finger wearing position
  • In-app pairing for ring ID 20540
  • Live PPG, EDA, temperature, and acceleration streaming
  • Session recording
  • Cloud sync checkmarks in Senstream

Not yet verified

  • charts.senstream.com web portal access
  • Long, stable streaming sessions
  • Integration with OpenBCI EEG
  • Mark Event button behavior
  • LED color or pattern meanings
  • Exact model printed on the lab package

End-of-session closeout

  1. Stop and save the recording in Senstream.
  2. Confirm the session appears in the selected storage location.
  3. If using Senstream Cloud, confirm the green cloud checkmark.
  4. Note any “No Finger” interruption or fit change in the session record.
  5. Return the ring to the magnetic charger when appropriate.